; DECOR ;--------------------------------------------------------------- ;! Measures the decorrelation between channels and IF of uv data ;# Task UV Calibration ;----------------------------------------------------------------------- ;; Copyright (C) 1995-1997, 2000, 2004, 2006, 2010 ;; Associated Universities, Inc. Washington DC, USA. ;; ;; This program is free software; you can redistribute it and/or ;; modify it under the terms of the GNU General Public License as ;; published by the Free Software Foundation; either version 2 of ;; the License, or (at your option) any later version. ;; ;; This program is distributed in the hope that it will be useful, ;; but WITHOUT ANY WARRANTY; without even the implied warranty of ;; MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the ;; GNU General Public License for more details. ;; ;; You should have received a copy of the GNU General Public ;; License along with this program; if not, write to the Free ;; Software Foundation, Inc., 675 Massachusetts Ave, Cambridge, ;; MA 02139, USA. ;; ;; Correspondence concerning AIPS should be addressed as follows: ;; Internet email: aipsmail@nrao.edu. ;; Postal address: AIPS Project Office ;; National Radio Astronomy Observatory ;; 520 Edgemont Road ;; Charlottesville, VA 22903-2475 USA ;----------------------------------------------------------------------- DECOR LLLLLLLLLLLLUUUUUUUUUUUU CCCCCCCCCCCCCCCCCCCCCCCCCCCCC DECOR Determines decorrelation between channels and IFs INNAME Input UV file name (name) INCLASS Input UV file name (class) INSEQ 0.0 9999.0 Input UV file name (seq. #) INDISK 0.0 9.0 Input UV file disk unit # SOURCES Source list QUAL -10.0 Source qualifier -1=>all CALCODE Calibrator code ' '=>all TIMERANG Time range to copy STOKES Stokes type to process. SELBAND Bandwidth to select (kHz) SELFREQ Frequency to select (MHz) FREQID Freq. ID to select. BIF 0.0 100.0 Lowest IF number 0=>all EIF 0.0 100.0 Highest IF number 0=>all BCHAN 0.0 2048.0 Lowest channel number 0=>all ECHAN 0.0 2048.0 Highest channel number SUBARRAY 0.0 1000.0 Subarray, 0=>all DOCALIB -1.0 101.0 > 0 calibrate data & weights > 99 do NOT calibrate weights GAINUSE CL (or SN) table to apply DOPOL -1.0 10.0 If >0 correct polarization. PDVER PD table to apply (DOPOL>0) BLVER BL table to apply. FLAGVER Flag table version DOBAND -1.0 10.0 If >0 apply bandpass cal. Method used depends on value of DOBAND (see HELP file). BPVER Bandpass table version SMOOTH Smoothing function. See HELP SMOOTH for details. OUTNAME Output UV file name (name) OUTCLASS Output UV file name (class) OUTSEQ -1.0 9999.0 Output UV file name (seq. #) OUTDISK 0.0 9.0 Output UV file disk unit #. ---------------------------------------------------------------- DECOR Task: This task measures the phase decorrelation among the various channels and IFs of a uv data set. The resulting data set will have it's real part the ratio of the scalar averaged amplitude of the selected data to the vector averaged amplitude and it's imaginary part set to zero. NOTE: this operation is only reasonable if the signal to noise ratio in the individual IF/channels is large enough that the amplitude bias is negligible. (A SNR > 10 should be adequate in many cases.) Adverbs: INNAME.....Input UV file name (name). Standard defaults. INCLASS....Input UV file name (class). Standard defaults. INSEQ......Input UV file name (seq. #). 0 => highest. INDISK.....Disk drive # of input UV file. 0 => any. SOURCES....Source list. ' ' or '*' = all; a "-" before a source name means all except ANY source named. QUAL.......Only sources with a source qualifier number in the SU table matching QUAL will be used if QUAL is not -1. CALCODE....Sources may be selected on the basis of the calibrator code given in the SU table. ' ' => any calibrator code selected '* ' => any non blank code (cal. only) '-CAL' => blank codes only (no calibrators) anything else = calibrator code to select. NB: The CALCODE test is applied in addition to the other tests, i.e. SOURCS and QUAL, in the selection of sources to process. TIMERANG...Time range of the data to be copied. In order: Start day, hour, min. sec, end day, hour, min. sec. Days relative to ref. date. STOKES.....The Stokes type to accept: 'I' (' ' => 'I') If the data is RR,LL,RL,LR the following are valid: 'RR', 'LL', 'RL', 'LR' If the data is in the form of IQUV then the following are valid: 'Q', 'U', 'V' SELBAND....Bandwidth of data to be selected. If more than one IF is present SELBAND is the width of the first IF required. Units = kHz. For data which contain multiple bandwidths/frequencies the task will insist that some form of selection be made by frequency or bandwidth. SELFREQ....Frequency of data to be selected. If more than one IF is present SELFREQ is the frequency of the first IF required. Units = MHz. FREQID.....Frequency identifier to select (you may determine which is applicable from the OPTYPE='SCAN' listing produced by LISTR). If either SELBAND or SELFREQ are set, their values overide that of FREQID. However, setting SELBAND and SELFREQ may result in an ambiguity. In that case, the task will request that you use FREQID. BIF........First IF to copy. 0=>all. EIF........Highest IF to copy. 0=>all higher than BIF BCHAN......First channel to copy. 0=>all. ECHAN......Highest channel to copy. 0=>all higher than BIF SUBARRAY...Subarray number to copy. 0=>all. DOCALIB....If true (>0), calibrate the data using information in the specified Cal (CL) table for multi-source or SN table for single-source data. Also calibrate the weights unless DOCALIB > 99 (use this for old non-physical weights). GAINUSE....Version number of the CL table to apply to multisource files or the SN table for single source files. 0 => highest. DOPOL......If > 0 then correct data for instrumental polarization as represented in the AN or PD table. This correction is only useful if PCAL has been run or feed polarization parameters have been otherwise obtained. See HELP DOPOL for available correction modes: 1 is normal, 2 and 3 are for VLBI. 1-3 use a PD table if available; 6, 7, 8 are the same but use the AN (continuum solution) even if a PD table is present. PDVER......PD table to apply if PCAL was run with SPECTRAL true and 0 < DOPOL < 6. <= 0 => highest. BLVER......Version number of the baseline based calibration (BL) table to appply. <0 => apply no BL table, 0 => highest. FLAGVER....specifies the version of the flagging table to be applied. 0 => highest numbered table. <0 => no flagging to be applied. DOBAND.....If true (>0) then correct the data for the shape of the antenna bandpasses using the BP table specified by BPVER. The correction has five modes: (a) if DOBAND=1 all entries for an antenna in the table are averaged together before correcting the data. (b) if DOBAND=2 the entry nearest in time (including solution weights) is used to correct the data. (c) if DOBAND=3 the table entries are interpolated in time (using solution weights) and the data are then corrected. (d) if DOBAND=4 the entry nearest in time (ignoring solution weights) is used to correct the data. (e) if DOBAND=5 the table entries are interpolated in time (ignoring solution weights) and the data are then corrected. BPVER......Specifies the version of the BP table to be applied plotted (if APARM(8)=2) or applied (if DOBAND > 0 and APARM(8) .NE. 2). 0 => highest numbered table. <0 => no bandpass correction to be applied. SMOOTH.....Specifies the type of spectral smoothing to be applied to a uv database . The default is not to apply any smoothing. The elements of SMOOTH are as follows: SMOOTH(1) = type of smoothing to apply: 0 => no smoothing To smooth before applying bandpass calibration 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc To smooth after applying bandpass calibration 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc SMOOTH(2) = the "diameter" of the function, i.e. width between first nulls of Hanning triangle and sinc function, FWHM of Gaussian, width of Boxcar. Defaults (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) = 1 - 4 and 5 - 8, resp. SMOOTH(3) = the diameter over which the convolving function has value - in channels. Defaults: 1,3,1,4 times SMOOTH(2) used when input SMOOTH(3) < net SMOOTH(2). OUTNAME....Output UV file name (name). Standard defaults. OUTCLASS...Output UV file name (class). Standard defaults. OUTSEQ.....Output UV file name (seq. #). 0 => highest unique OUTDISK....Disk drive # of output UV file. 0 => highest with space for the file. ----------------------------------------------------------------