; BSCAN ;--------------------------------------------------------------- ;! seeks best scan to use for phase cal, fringe search, .. ;# Task UV VLBI ;----------------------------------------------------------------------- ;; Copyright (C) 2012-2014 ;; Associated Universities, Inc. Washington DC, USA. ;; ;; This program is free software; you can redistribute it and/or ;; modify it under the terms of the GNU General Public License as ;; published by the Free Software Foundation; either version 2 of ;; the License, or (at your option) any later version. ;; ;; This program is distributed in the hope that it will be useful, ;; but WITHOUT ANY WARRANTY; without even the implied warranty of ;; MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the ;; GNU General Public License for more details. ;; ;; You should have received a copy of the GNU General Public ;; License along with this program; if not, write to the Free ;; Software Foundation, Inc., 675 Massachusetts Ave, Cambridge, ;; MA 02139, USA. ;; ;; Correspondence concerning AIPS should be addressed as follows: ;; Internet email: aipsmail@nrao.edu. ;; Postal address: AIPS Project Office ;; National Radio Astronomy Observatory ;; 520 Edgemont Road ;; Charlottesville, VA 22903-2475 USA ;----------------------------------------------------------------------- BSCAN LLLLLLLLLLLLUUUUUUUUUUUU CCCCCCCCCCCCCCCCCCCCCCCCCCCCC BSCAN seeks best scan to use for phase-cal, fringe-search, INNAME Input UV file name (name) INCLASS Input UV file name (class) INSEQ 0.0 9999.0 Input UV file name (seq. #) INDISK 0.0 9.0 Input UV file disk unit # SOURCES Source name: give only 1 QUAL -10.0 Calibrator qualifier -1=>all CALCODE Calibrator code ' '=>all TIMERANG Time range to use SELBAND Bandwidth to select (kHz) SELFREQ Frequency to select (MHz) FREQID Freq. ID to select. SUBARRAY 0.0 1000.0 Sub-array, 0=>all BIF Low IF number to do EIF Highest IF number to do BCHAN 0.0 First channel included ECHAN 0.0 last channel included DOCALIB -1.0 101.0 > 0 calibrate data & weights > 99 do NOT calibrate weights GAINUSE CL (or SN) table to apply DOPOL -1.0 10.0 If >0.5 correct polarization. PDVER PD table to apply (DOPOL>0) BLVER BL table to apply. FLAGVER Flag table version DOBAND -1.0 10.0 If >0.5 apply bandpass cal. Method used depends on value of DOBAND (see HELP file). BPVER Bandpass table version SMOOTH Smoothing function. See HELP SMOOTH for details. ANTUSE list of antennas to ignore INVERS PC table version top check <= 0 -> none. CHANSEL @ Output: start/stop time, #ant APARM @ Output: (1) missing antenna ---------------------------------------------------------------- BSCAN Task: This task will examine each scan of one source in a data set to see which scan has data from all antennas. If necessary it will return information about two scans. Adverbs: INNAME.....Input UV file name (name). Standard defaults. INCLASS....Input UV file name (class). Standard defaults. INSEQ......Input UV file name (seq. #). 0 => highest. INDISK.....Disk drive # of input UV file. 0 => any. SOURCES....Source to be studied. Only SOURCE(1) is used. QUAL.......Qualifier of source to be studied. -1 => all. CALCODE....Calibrator code of sources to study. ' '=> all. TIMERANG...Time range of the data to be studied. In order: Start day, hour, min. sec, end day, hour, min. sec. Days relative to ref. date. SELBAND....Bandwidth of data to be selected. If more than one IF is present SELBAND is the width of the first IF required. Units = kHz. For data which contain multiple bandwidths/frequencies the task will insist that some form of selection be made by frequency or bandwidth. SELFREQ....Frequency of data to be selected. If more than one IF is present SELFREQ is the frequency of the first IF required. Units = MHz. FREQID.....Frequency identifier to select (you may determine which is applicable from the OPTYPE='SCAN' listing produced by LISTR). If either SELBAND or SELFREQ are set, their values override that of FREQID. However, setting SELBAND and SELFREQ may result in an ambiguity. In that case, the task will request that you use FREQID. SUBARRAY...Sub-array number to copy. 0=>all. BIF........First IF to include. 0 -> 1. EIF........Last IF to include. 0 -> max. BCHAN......First channel to copy. 0=>all. ECHAN......Highest channel to copy. 0=>all higher than BCHAN DOCALIB....If true (>0), calibrate the data using information in the specified Cal (CL) table for multi-source or SN table for single-source data. Also calibrate the weights unless DOCALIB > 99 (use this for old non-physical weights). GAINUSE....version number of the CL table to apply to multi-source files or the SN table for single source files. 0 => highest. DOPOL......If > 0 then correct data for instrumental polarization as represented in the AN or PD table. This correction is only useful if PCAL has been run or feed polarization parameters have been otherwise obtained. See HELP DOPOL for available correction modes: 1 is normal, 2 and 3 are for VLBI. 1-3 use a PD table if available; 6, 7, 8 are the same but use the AN (continuum solution) even if a PD table is present. PDVER......PD table to apply if PCAL was run with SPECTRAL true and 0 < DOPOL < 6. <= 0 => highest. BLVER......Version number of the baseline based calibration (BL) table to apply. <0 => apply no BL table, 0 => highest. FLAGVER....specifies the version of the flagging table to be applied. 0 => highest numbered table. <0 => no flagging to be applied. DOBAND.....If true (>0) then correct the data for the shape of the antenna bandpasses using the BP table specified by BPVER. The correction has five modes: (a) if DOBAND=1 all entries for an antenna in the table are averaged together before correcting the data. (b) if DOBAND=2 the entry nearest in time (including solution weights) is used to correct the data. (c) if DOBAND=3 the table entries are interpolated in time (using solution weights) and the data are then corrected. (d) if DOBAND=4 the entry nearest in time (ignoring solution weights) is used to correct the data. (e) if DOBAND=5 the table entries are interpolated in time (ignoring solution weights) and the data are then corrected. IMAGR uses DOBAND as the nearest integer; 0.1 is therefore "false". BPVER......Specifies the version of the BP table to be applied 0 => highest numbered table. <0 => no bandpass correction to be applied. SMOOTH.....Specifies the type of spectral smoothing to be applied to a uv database . The default is not to apply any smoothing. The elements of SMOOTH are as follows: SMOOTH(1) = type of smoothing to apply: 0 => no smoothing To smooth before applying bandpass calibration 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc To smooth after applying bandpass calibration 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc SMOOTH(2) = the "diameter" of the function, i.e. width between first nulls of Hanning triangle and sinc function, FWHM of Gaussian, width of Boxcar. Defaults (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) = 1 - 4 and 5 - 8, resp. SMOOTH(3) = the diameter over which the convolving function has value - in channels. Defaults: 1,3,1,4 times SMOOTH(2) used when input SMOOTH(3) < net SMOOTH(2). ANTUSE.....List of antenna numbers to be ignored. INVERS.....If > 0, require that a scan have at least one PC table entry in order to be considered. INVERS is the version of the PC table that should be used. Output adverbs: CHANSEL....CHANSEL(1,i) start time of scan i CHANSEL(2,i) stop time of scan i (0.0 => none) CHANSEL(3,i) number of antennas in scan i 0 -> none APARM......(1) antenna number missing from first scan above; 0 -> none. ----------------------------------------------------------------