; FGCNT ;--------------------------------------------------------------- ;! Counts samples comparing two flag tables ;# Task UV Editing ;----------------------------------------------------------------------- ;; Copyright (C) 2016 ;; Associated Universities, Inc. Washington DC, USA. ;; ;; This program is free software; you can redistribute it and/or ;; modify it under the terms of the GNU General Public License as ;; published by the Free Software Foundation; either version 2 of ;; the License, or (at your option) any later version. ;; ;; This program is distributed in the hope that it will be useful, ;; but WITHOUT ANY WARRANTY; without even the implied warranty of ;; MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the ;; GNU General Public License for more details. ;; ;; You should have received a copy of the GNU General Public ;; License along with this program; if not, write to the Free ;; Software Foundation, Inc., 675 Massachusetts Ave, Cambridge, ;; MA 02139, USA. ;; ;; Correspondence concerning AIPS should be addressed as follows: ;; Internet email: aipsmail@nrao.edu. ;; Postal address: AIPS Project Office ;; National Radio Astronomy Observatory ;; 520 Edgemont Road ;; Charlottesville, VA 22903-2475 USA ;----------------------------------------------------------------------- FGCNT LLLLLLLLLLLLUUUUUUUUUUUU CCCCCCCCCCCCCCCCCCCCCCCCCCCCC FGCNT counts samples flagged to compare two flag tables INNAME Input UV file name (name) INCLASS Input UV file name (class) INSEQ 0.0 9999.0 Input UV file name (seq. #) INDISK 0.0 9.0 Input UV file disk unit # SOURCES Source name QUAL -10.0 Calibrator qualifier -1=>all CALCODE Calibrator code ' '=>all STOKES Stokes of output TIMERANG Time range to use SELBAND Bandwidth to select (kHz) SELFREQ Frequency to select (MHz) FREQID Freq. ID to select. ANTENNAS Antennas to copy 0=>all BASELINE Baselines with ANTENNAS SUBARRAY 0.0 1000.0 Sub-array, 0=>all BIF Low IF number to do EIF Highest IF number to do BCHAN 0.0 First channel included ECHAN 0.0 last channel included DOCALIB -1.0 101.0 > 0 calibrate data & weights > 99 do NOT calibrate weights GAINUSE CL (or SN) table to apply DOPOL -1.0 10.0 If >0.5 correct polarization. PDVER PD table to apply (DOPOL>0) BLVER BL table to apply. FLAGVER Flag table version for before 0 -> -1 IN2VERS Flag table version for after 0 -> max DOBAND -1.0 10.0 If >0.5 apply bandpass cal. Method used depends on value of DOBAND (see HELP file). BPVER Bandpass table version SMOOTH Smoothing function. See HELP SMOOTH for details. DOACOR Include autocorrelations? OPTYPE ' ' list by source, IF, pol. 'ANTE' list by source, pol., and antenna (not IF) 'ANIF' list by source, pol., antenna and IF ---------------------------------------------------------------- FGCNT Task: This task applies the calibration and flagging software to a data set and counts the samples under a "before" flag table (FLAGVER, default none) and an "after" flag table (IN2VERS, default maximum FG version). It then prints the number of correlations found by polarization, IF, and source showing percentage lost between the two flag tables. Displays that separate counts by antenna are also available. Adverbs: INNAME.....Input UV file name (name). Standard defaults. INCLASS....Input UV file name (class). Standard defaults. INSEQ......Input UV file name (seq. #). 0 => highest. INDISK.....Disk drive # of input UV file. 0 => any. SOURCES....Source to be copied. ' '=> all; if any starts with a '-' then all except ANY source named. QUAL.......Qualifier of source to be copied. -1 => all. CALCODE....Calibrator code of sources to copy. ' '=> all. STOKES.....Specifies which STOKES parameters are written in the output data set: ' ' => 'FULL' 'I','Q','U','V', 'IV', 'IQU', 'IQUV' 'RR','LL', 'RL', 'LR', 'RRLL', 'RLLR', 'RLRL' 'XX','YY', 'XY', 'YX', 'XXYY', 'XYYX', 'XYXY' 'HALF', 'CROS', and 'FULL' have sensible interpretations depending on the Stokes present in the data. The last in each of the 3 rows above == 'FULL'. Note that many combinations of polarizations in the input and values above are not supported. TIMERANG...Time range of the data to be copied. In order: Start day, hour, min. sec, end day, hour, min. sec. Days relative to ref. date. SELBAND....Bandwidth of data to be selected. If more than one IF is present SELBAND is the width of the first IF required. Units = kHz. For data which contain multiple bandwidths/frequencies the task will insist that some form of selection be made by frequency or bandwidth. SELFREQ....Frequency of data to be selected. If more than one IF is present SELFREQ is the frequency of the first IF required. Units = MHz. FREQID.....Frequency identifier to select (you may determine which is applicable from the OPTYPE='SCAN' listing produced by LISTR). If either SELBAND or SELFREQ are set, their values override that of FREQID. However, setting SELBAND and SELFREQ may result in an ambiguity. In that case, the task will request that you use FREQID. ANTENNAS...A list of the antennas to be copied. All 0 => all. If any number is negative then all antennas listed are NOT to be copied and all others are. BASELINE...Baselines between antennas named in ANTENNAS and those named in BASELINE are selected.. There are four possible combinations of ANTENNAS and BASELINE: 1. ANTENNAS = 0; BASELINE = 0. All possible baselines are selected. 2. ANTENNAS <>0; BASELINE = 0. a)All ANTENNAS > 0 Baselines including an antenna in the ANTENNAS list are selected; b)Some ANTENNAS < 0 All baselines NOT including an antenna in the ANTENNAS list are selected; 3. ANTENNAS = 0; BASELINE <> 0. a)All BASELINE > 0 Baselines including an antenna in the BASELINE list are selected; b)Some BASELINE < 0 All baselines NOT including an antenna in the BASELINE list are selected; 4. ANTENNAS <> 0; BASELINE <> 0. a)All ANTENNAS>0 and all BASELINE>0 Baselines between antennas named in ANTENNAS and those named in BASELINE are selected. b)Some ANTENNAS<0 .OR. some BASELINE<0 Baselines between antennas named in ANTENNAS and those named in BASELINE are DE-selected, all others are selected. SUBARRAY...Sub-array number to copy. 0=>all. BIF........First IF to include. 0 -> 1. EIF........Last IF to include. 0 -> max. BCHAN......First channel to copy. 0=>all. ECHAN......Highest channel to copy. 0=>all higher than BCHAN DOCALIB....If true (>0), calibrate the data using information in the specified Cal (CL) table for multi-source or SN table for single-source data. Also calibrate the weights unless DOCALIB > 99 (use this for old non-physical weights). GAINUSE....version number of the CL table to apply to multi-source files or the SN table for single source files. 0 => highest. DOPOL......If > 0 then correct data for instrumental polarization as represented in the AN or PD table. This correction is only useful if PCAL has been run or feed polarization parameters have been otherwise obtained. See HELP DOPOL for available correction modes: 1 is normal, 2 and 3 are for VLBI. 1-3 use a PD table if available; 6, 7, 8 are the same but use the AN (continuum solution) even if a PD table is present. PDVER......PD table to apply if PCAL was run with SPECTRAL true and 0 < DOPOL < 6. <= 0 => highest. BLVER......Version number of the baseline based calibration (BL) table to apply. <0 => apply no BL table, 0 => highest. FLAGVER....specifies the version of the flagging table to be applied in the "before" count. <= 0 => no flagging "before" IN2VERS....specifies the version of the flagging table to be applied in the "after" count. <= 0 => max version "after" DOBAND.....If true (>0) then correct the data for the shape of the antenna bandpasses using the BP table specified by BPVER. The correction has five modes: (a) if DOBAND=1 all entries for an antenna in the table are averaged together before correcting the data. (b) if DOBAND=2 the entry nearest in time (including solution weights) is used to correct the data. (c) if DOBAND=3 the table entries are interpolated in time (using solution weights) and the data are then corrected. (d) if DOBAND=4 the entry nearest in time (ignoring solution weights) is used to correct the data. (e) if DOBAND=5 the table entries are interpolated in time (ignoring solution weights) and the data are then corrected. IMAGR uses DOBAND as the nearest integer; 0.1 is therefore "false". BPVER......Specifies the version of the BP table to be applied 0 => highest numbered table. <0 => no bandpass correction to be applied. SMOOTH.....Specifies the type of spectral smoothing to be applied to a uv database . The default is not to apply any smoothing. The elements of SMOOTH are as follows: SMOOTH(1) = type of smoothing to apply: 0 => no smoothing To smooth before applying bandpass calibration 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc To smooth after applying bandpass calibration 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc SMOOTH(2) = the "diameter" of the function, i.e. width between first nulls of Hanning triangle and sinc function, FWHM of Gaussian, width of Boxcar. Defaults (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) = 1 - 4 and 5 - 8, resp. SMOOTH(3) = the diameter over which the convolving function has value - in channels. Defaults: 1,3,1,4 times SMOOTH(2) used when input SMOOTH(3) < net SMOOTH(2). DOACOR.....> 0 => include autocorrelations as well as cross correlation data. OPTYPE.....'ANIF' => list by source, antenna, IF, and polarization 'ANTE' => list by source, antenna, and polarization (IFs summed) else => list by source, IF, and polarization (antennas summed) ----------------------------------------------------------------