AIPS NRAO AIPS HELP file for FGSPW in 31DEC25



As of Wed Dec 11 6:35:46 2024


FGSPW: Flags bad spectral windows

INPUTS

INNAME                             Input UV file name (name)
INCLASS                            Input UV file name (class)
INSEQ             0.0     9999.0   Input UV file name (seq. #)
INDISK            0.0        9.0   Input UV file disk unit #
SOURCES                            Source name
QUAL            -10.0              Calibrator qualifier -1=>all
CALCODE                            Calibrator code '    '=>all
TIMERANG                           Time range to use
SELBAND                            Bandwidth to select (kHz)
SELFREQ                            Frequency to select (MHz)
FREQID                             Freq. ID to select.
SUBARRAY          0.0     1000.0   Sub-array, 0=>all
BIF                                Low IF number to do
EIF                                Highest IF number to do
BCHAN             0.0              First channel included
ECHAN             0.0              last channel included
DOCALIB          -1.0      101.0   > 0 calibrate data & weights
                                   > 99 do NOT calibrate weights
GAINUSE                            CL (or SN) table to apply
DOPOL            -1.0       10.0   If >0.5 correct polarization.
PDVER                              PD table to apply (DOPOL>0)
BLVER                              BL table to apply.
FLAGVER                            Flag table version
DOBAND           -1.0       10.0   If >0.5 apply bandpass cal.
                                   Method used depends on value
                                   of DOBAND (see HELP file).
BPVER                              Bandpass table version
SMOOTH                             Smoothing function. See
                                   HELP SMOOTH for details.
OUTFGVER                           Output flag table version
                                   0 -> new one
SOLINT                             Averaging time (minutes)
                                   0 -> scan
APARM                              (1) Flag all parallel hands
                                       above APARM(1)
                                   (2) Flag all cross-hands
                                       above APARM(2)
                                   (3) > 0 If one is bad, flag
                                       all polarizations
                                   (4) > 0 => APARM(1) and (2)
                                       are in Jy/flux
BADDISK                            Disks to avoid for scratch

HELP SECTION

FGSPW
Task:  This task will perform a matrix scalar average of amplitudes in
       each included scan,  It then flags those baselines and
       polarizations with excessive amplitude.  The average is over
       all spectral channels in each spectral window and all are
       flagged when the spectral window (aka "IF" in AIPS) is
       flagged.  This operation is designed to catch those windows
       where amplitudes have ovflowed the hardware due to RFI within
       the spectral window.
Adverbs:
  INNAME.....Input UV file name (name).      Standard defaults.
  INCLASS....Input UV file name (class).     Standard defaults.
  INSEQ......Input UV file name (seq. #).    0 => highest.
  INDISK.....Disk drive # of input UV file.  0 => any.
  SOURCES....Sources to be checked.   '  '=> all; if any starts with a
             '-' then all except ANY source named.
  QUAL.......Qualifier of source to be checked. -1 => all.
  CALCODE....Calibrator code of sources to check. ' '=> all.
  TIMERANG...Time range of the data to be checked. In order: Start day,
             hour, min. sec, end day, hour, min. sec. Days relative to
             ref. date.
  SELBAND....Bandwidth of data to be selected. If more than one IF is
             present SELBAND is the width of the first IF required.
             Units = kHz. For data which contain multiple
             bandwidths/frequencies the task will insist that some form
             of selection be made by frequency or bandwidth.
  SELFREQ....Frequency of data to be selected. If more than one IF is
             present SELFREQ is the frequency of the first IF required.
             Units = MHz.
  FREQID.....Frequency identifier to select (you may determine which is
             applicable from the OPTYPE='SCAN' listing produced by
             LISTR). If either SELBAND or SELFREQ are set, their values
             override that of FREQID.  However, setting SELBAND and
             SELFREQ may result in an ambiguity.  In that case, the task
             will request that you use FREQID.
  SUBARRAY...Sub-array number to copy. 0=>all.
  BIF........First IF to include.  0 -> 1.
  EIF........Last IF to include.   0 -> max.
  BCHAN......First channel to include. 0=>all.
  ECHAN......Highest channel to include. 0=>all higher than BCHAN
  DOCALIB....If true (>0), calibrate the data using information in the
             specified Cal (CL) table for multi-source or SN table for
             single-source data.  Also calibrate the weights unless
             DOCALIB > 99 (use this for old non-physical weights).
  GAINUSE....version number of the CL table to apply to multi-source
             files or the SN table for single source files.
             0 => highest.
  DOPOL......If > 0 then correct data for instrumental polarization as
             represented in the AN or PD table.  This correction is
             only useful if PCAL has been run or feed polarization
             parameters have been otherwise obtained.  See HELP DOPOL
             for available correction modes: 1 is normal, 2 and 3 are
             for VLBI.  1-3 use a PD table if available; 6, 7, 8 are
             the same but use the AN (continuum solution) even if a PD
             table is present.
  PDVER......PD table to apply if PCAL was run with SPECTRAL true and
             0 < DOPOL < 6.  <= 0 => highest.
  BLVER......Version number of the baseline based calibration (BL) table
             to apply. <0 => apply no BL table, 0 => highest.
  FLAGVER....specifies the version of the flagging table to be applied.
              0 => highest numbered table.
             <0 => no flagging to be applied.
  DOBAND.....If true (>0) then correct the data for the shape of the
             antenna bandpasses using the BP table specified by BPVER.
             The correction has five modes:
             (a) if DOBAND=1 all entries for an antenna in the table
             are averaged together before correcting the data.
             (b) if DOBAND=2 the entry nearest in time (including
             solution weights) is used to correct the data.
             (c) if DOBAND=3 the table entries are interpolated in
             time (using solution weights) and the data are then
             corrected.
             (d) if DOBAND=4 the entry nearest in time (ignoring
             solution weights) is used to correct the data.
             (e) if DOBAND=5 the table entries are interpolated in
             time (ignoring solution weights) and the data are then
             corrected.
             IMAGR uses DOBAND as the nearest integer; 0.1 is therefore
             "false".
  BPVER......Specifies the version of the BP table to be applied
                0 => highest numbered table.
               <0 => no bandpass correction to be applied.
  SMOOTH.....Specifies the type of spectral smoothing to be applied to
             a uv database . The default is not to apply any smoothing.
             The elements of SMOOTH are as follows:
             SMOOTH(1) = type of smoothing to apply: 0 => no smoothing
               To smooth before applying bandpass calibration
                 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc
               To smooth after applying bandpass calibration
                 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc
             SMOOTH(2) = the "diameter" of the function, i.e. width
               between first nulls of Hanning triangle and sinc
               function, FWHM of Gaussian, width of Boxcar. Defaults
               (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) =
               1 - 4 and 5 - 8, resp.
             SMOOTH(3) = the diameter over which the convolving
               function has value - in channels.  Defaults: 1,3,1,4
               times SMOOTH(2) used when input SMOOTH(3) < net
               SMOOTH(2).
  OUTFGVER...Output flag table version.  0 -> new one and FLAGVER is
             copied to the new one ahead of any flagging.
  APARM......(1) Flag all parallel hands > APARM(1) Jy or Jy/flux
             (2) Flag all cross hands > APARM(2) Jy or Jy/flux
             (3) > Flag all polarizations if any one is bad
             (4) > 0 -> APARM(1) and APARM(2) are in Jy / flux
                 and so are multiplied by the fluxes in the SU table
                 before the comparison is done.
  BADDISK....The disk numbers to avoid for scratch files (sorting
             tables mostly).

EXPLAIN SECTION


AIPS