AIPS HELP file for ANTUSE in 31DEC24
As of Mon Sep 16 7:50:11 2024
HELP SECTION
ANTUSE
Type: Adverb (REAL(50))
Use: Standard data selection adverb, used to specify a list of antennas
to be included in, or excluded from, an operation. If any element
of the array is negative then all antennas given are excluded;
else all are included. The antenna numbers used are the absolute
values of the elements of ANTUSE.
Null Value: 0
ANTUSE = 0 usually means all antennas.
ANTUSE is often used to specify the subgroup of antennas having
been selected by ANTENNAS
Tasks:
BPEDT.....Interactive TV task to edit uv data based on BP tables.
ANTUSE selects the antennas in the initial display.
BSCAN.....Seeks best scan to use for phase cal, fringe search.
ANTUSE is a list of antennas to be ignored.
CALIB.....Determines antenna calibration: complex gain. ANTUSE is a
list of antennas to be used in determining the mean gain.
EDITA.....Interactive TV task to edit uv data based on TY/SY/SN/CL
tables. ANTUSE selects the antennas in the initial
display.
EDITR.....Interactive baseline-oriented visibility editor using the
TV. ANTUSE selects the antennas in the initial display.
PCEDT.....Interactive TV task to edit pulse-cal (PC) tables.
ANTUSE selects the antennas in the initial display.
PDEDT.....Interactive TV task to edit polarization D-term (PD)
tables. ANTUSE selects the antennas in the initial
display.
SNEDT.....Interactive SN/CL/TY/SY table editor using the TV.
ANTUSE selects the antennas in the initial display.
Procedures:
IMSCAL....Large image self-cal with IM2CC and OOCAL. ANTUSE lists the
antennas to be used to find the mean gain.
OOCAL.....Determines antenna complex gain with frequency-dependent
models. ANTUSE lists the antennas to be used to find the
mean gain.