AIPS HELP file for SUFIX in 31DEC25
As of Wed Dec 11 8:29:30 2024
SUFIX: Changes source number for specified time ranges
INPUTS
INNAME Input UV file name (name)
INCLASS Input UV file name (class)
INSEQ 0.0 9999.0 Input UV file name (seq. #)
INDISK 0.0 9.0 Input UV file disk unit #
SOURCES Source name
QUAL -10.0 Calibrator qualifier -1=>all
CALCODE Calibrator code ' '=>all
STOKES Stokes of output
TIMERANG Time range to use
SELBAND Bandwidth to select (kHz)
SELFREQ Frequency to select (MHz)
FREQID Freq. ID to select.
SUBARRAY 0.0 1000.0 Sub-array, 0=>all
BIF Low IF number to do
EIF Highest IF number to do
BCHAN 0.0 First channel included
ECHAN 0.0 last channel included
DOCALIB -1.0 101.0 > 0 calibrate data & weights
> 99 do NOT calibrate weights
GAINUSE CL (or SN) table to apply
DOPOL -1.0 10.0 If >0.5 correct polarization.
PDVER PD table to apply (DOPOL>0)
BLVER BL table to apply.
FLAGVER Flag table version
DOBAND -1.0 10.0 If >0.5 apply bandpass cal.
Method used depends on value
of DOBAND (see HELP file).
BPVER Bandpass table version
SMOOTH Smoothing function. See
HELP SMOOTH for details.
DOACOR Include autocorrelations?
OUTNAME Output UV file name (name)
OUTCLASS Output UV file name (class)
OUTSEQ -1.0 9999.0 Output UV file name (seq. #)
OUTDISK 0.0 9.0 Output UV file disk unit #.
FPARM 0.0 Start times (days)
RPARM 0.0 Stop times (days)
KEYSTRNG New source name
SOUCODE Calcode to assign new source
COORDINA New source coordinates
BADDISK Disks to avoid for scratch
HELP SECTION
SUFIX
Task: This task will create a new source number in the source table
and assign it to all data which occur in up to 30 time
intervals. Calibration, source selection, etc are available
but may not be appropriate in many cases. This task works only
on a multi-source input file. If the KEYSTRNG, SOUCODE, and
COORDINA match those of an existing source, then that source
number rather than a new one will be substituted in the time
range(s). SUFIX does not work for moving sources (i.e. those
described by a PO table).
Adverbs:
INNAME.....Input UV file name (name). Standard defaults.
INCLASS....Input UV file name (class). Standard defaults.
INSEQ......Input UV file name (seq. #). 0 => highest.
INDISK.....Disk drive # of input UV file. 0 => any.
SOURCES....Source to be copied. ' '=> all; if any starts with a
'-' then all except ANY source named.
QUAL.......Qualifier of source to be copied. -1 => all.
CALCODE....Calibrator code of sources to copy. ' '=> all.
STOKES.....Specifies which STOKES parameters are written in the
output data set: ' ' => 'FULL'
'I','Q','U','V', 'IV', 'IQU', 'IQUV'
'RR','LL', 'RL', 'LR', 'RRLL', 'RLLR', 'RLRL'
'VV','HH', 'VH', 'HV', 'VVHH', 'VHHV', 'VHVH'
'HALF', 'CROS', and 'FULL' have sensible interpretations
depending on the Stokes present in the data. The last in
each of the 3 rows above == 'FULL'. Note that many
combinations of polarizations in the input and values
above are not supported.
TIMERANG...Time range of the data to be copied. In order: Start day,
hour, min. sec, end day, hour, min. sec. Days relative to
ref. date.
SELBAND....Bandwidth of data to be selected. If more than one IF is
present SELBAND is the width of the first IF required.
Units = kHz. For data which contain multiple
bandwidths/frequencies the task will insist that some form
of selection be made by frequency or bandwidth.
SELFREQ....Frequency of data to be selected. If more than one IF is
present SELFREQ is the frequency of the first IF required.
Units = MHz.
FREQID.....Frequency identifier to select (you may determine which is
applicable from the OPTYPE='SCAN' listing produced by
LISTR). If either SELBAND or SELFREQ are set, their values
override that of FREQID. However, setting SELBAND and
SELFREQ may result in an ambiguity. In that case, the task
will request that you use FREQID.
SUBARRAY...Sub-array number to copy. 0=>all.
BIF........First IF to include. 0 -> 1.
EIF........Last IF to include. 0 -> max.
BCHAN......First channel to copy. 0=>all.
ECHAN......Highest channel to copy. 0=>all higher than BCHAN
DOCALIB....If true (>0), calibrate the data using information in the
specified Cal (CL) table for multi-source or SN table for
single-source data. Also calibrate the weights unless
DOCALIB > 99 (use this for old non-physical weights).
GAINUSE....version number of the CL table to apply to multi-source
files or the SN table for single source files.
0 => highest.
DOPOL......If > 0 then correct data for instrumental polarization as
represented in the AN or PD table. This correction is
only useful if PCAL has been run or feed polarization
parameters have been otherwise obtained. See HELP DOPOL
for available correction modes: 1 is normal, 2 and 3 are
for VLBI. 1-3 use a PD table if available; 6, 7, 8 are
the same but use the AN (continuum solution) even if a PD
table is present.
PDVER......PD table to apply if PCAL was run with SPECTRAL true and
0 < DOPOL < 6. <= 0 => highest.
BLVER......Version number of the baseline based calibration (BL) table
to apply. <0 => apply no BL table, 0 => highest.
FLAGVER....specifies the version of the flagging table to be applied.
0 => highest numbered table.
<0 => no flagging to be applied.
DOBAND.....If true (>0) then correct the data for the shape of the
antenna bandpasses using the BP table specified by BPVER.
The correction has five modes:
(a) if DOBAND=1 all entries for an antenna in the table
are averaged together before correcting the data.
(b) if DOBAND=2 the entry nearest in time (including
solution weights) is used to correct the data.
(c) if DOBAND=3 the table entries are interpolated in
time (using solution weights) and the data are then
corrected.
(d) if DOBAND=4 the entry nearest in time (ignoring
solution weights) is used to correct the data.
(e) if DOBAND=5 the table entries are interpolated in
time (ignoring solution weights) and the data are then
corrected.
IMAGR uses DOBAND as the nearest integer; 0.1 is therefore
"false".
BPVER......Specifies the version of the BP table to be applied
0 => highest numbered table.
<0 => no bandpass correction to be applied.
SMOOTH.....Specifies the type of spectral smoothing to be applied to
a uv database . The default is not to apply any smoothing.
The elements of SMOOTH are as follows:
SMOOTH(1) = type of smoothing to apply: 0 => no smoothing
To smooth before applying bandpass calibration
1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc
To smooth after applying bandpass calibration
5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc
SMOOTH(2) = the "diameter" of the function, i.e. width
between first nulls of Hanning triangle and sinc
function, FWHM of Gaussian, width of Boxcar. Defaults
(if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) =
1 - 4 and 5 - 8, resp.
SMOOTH(3) = the diameter over which the convolving
function has value - in channels. Defaults: 1,3,1,4
times SMOOTH(2) used when input SMOOTH(3) < net
SMOOTH(2).
DOACOR.....> 0 => include autocorrelations as well as cross
correlation data.
OUTNAME....Output UV file name (name). Standard defaults.
OUTCLASS...Output UV file name (class). Standard defaults.
OUTSEQ.....Output UV file name (seq. #). 0 => highest unique
OUTDISK....Disk drive # of output UV file. 0 => highest with space
for the file.
FPARM......Array of up to 30 start times in days
RPARM......Matching array of stop times in days.
RPARM(i) < FPARM(i) or FPARM(i) or RPARM(i) = 0
stops the list.
KEYSTRNG...Name to assign new source: ' ' => 'NEW SOURCE'
If this and the follow match an existing source, that
source number will be used.
SOUCODE....Calcode to assign new source, no default
If this and the above and below match an existing source,
that source number will be used.
COORDINA...Coordinates of new source in B1950 or J2000 as the
other sources in the data set. If this and the above two
adverbs match an existing source, that source number will
be used rather than a new number.
BADDISK....The disk numbers to avoid for scratch files (sorting
tables mostly).
EXPLAIN SECTION