UV2TB: Converts UV autocorrelation spectra to tables

INPUTS

INNAME                             Input UV file name (name)
INCLASS                            Input UV file name (class)
INSEQ             0.0     9999.0   Input UV file name (seq. #)
INDISK            0.0        9.0   Input UV file disk unit #
SOURCES                            Source list
QUAL            -10.0              Source qualifier -1=>all
CALCODE                            Calibrator code '    '=>all
TIMERANG                           Time range to copy
STOKES                             Stokes type to process.
SELBAND                            Bandwidth to select (kHz)
SELFREQ                            Frequency to select (MHz)
FREQID                             Freq. ID to select.
BIF               0.0      100.0   Lowest IF number 0=>all
EIF               0.0      100.0   Highest IF number 0=>all
BCHAN             0.0     2048.0   Lowest channel number 0=>all
ECHAN             0.0     2048.0   Highest channel number
SUBARRAY          0.0     1000.0   Subarray, 0=>all
DOCALIB          -1.0      101.0   > 0 calibrate data & weights
                                   > 99 do NOT calibrate weights
GAINUSE                            CL (or SN) table to apply
DOPOL            -1.0       10.0   If >0 correct polarization.
PDVER                              PD table to apply (DOPOL>0)
BLVER                              BL table to apply.
FLAGVER                            Flag table version
DOBAND           -1.0       10.0   If >0 apply bandpass cal.
                                   Method used depends on value
                                   of DOBAND (see HELP file).
BPVER                              Bandpass table version
SMOOTH                             Smoothing function. See
                                   HELP SMOOTH for details.
OUTVER            0.0   46655.0    Output AS spectrum table
BADDISK                            Disks to avoid for scratch

HELP SECTION

UV2TB
Task:  This task writes autocorrelation spectra into a table of
       type AS.  Each autocorrelation visibility in the input uv
       data is written into a separate row of the table.

Adverbs:
  INNAME.....Input UV file name (name).      Standard defaults.
  INCLASS....Input UV file name (class).     Standard defaults.
  INSEQ......Input UV file name (seq. #).    0 => highest.
  INDISK.....Disk drive # of input UV file.  0 => any.
  SOURCES....Source list.  '  ' or '*' = all;
             a "-" before a source name means all except ANY
             source named.
  QUAL.......Only sources with a source qualifier number in the
             SU table matching QUAL will be used if QUAL is not
             -1.
  CALCODE....Sources may be selected on the basis of the
             calibrator code given in the SU table.
                  '    ' => any calibrator code selected
                  '*   ' => any non blank code (cal. only)
                  '-CAL' => blank codes only (no calibrators)
                  anything else = calibrator code to select.
             NB: The CALCODE test is applied in addition to the
             other tests, i.e. SOURCS and QUAL, in the
             selection of sources to process.
  TIMERANG...Time range of the data to be copied. In order:
             Start day, hour, min. sec,
             end day, hour, min. sec. Days relative to ref.
             date.
  STOKES.....The Stokes type to accept:
             'I'  ('  ' => 'I')
              If the data is RR,LL,RL,LR the following are
              valid: 'RR', 'LL', 'RL', 'LR'
              If the data is in the form of IQUV then the
              following are valid: 'Q', 'U', 'V'
  SELBAND....Bandwidth of data to be selected. If more than
             one IF is present SELBAND is the width of the
             first IF required. Units = kHz. For data which
             contain multiple bandwidths/frequencies the task
             will insist that some form of selection be made
             by frequency or bandwidth.
  SELFREQ....Frequency of data to be selected. If more than
             one IF is present SELFREQ is the frequency of the
             first IF required. Units = MHz.
  FREQID.....Frequency identifier to select (you may determine
             which is applicable from the OPTYPE='SCAN' listing
             produced by LISTR). If either SELBAND or SELFREQ
             are set, their values overide that of FREQID.
             However, setting SELBAND and SELFREQ may result in
             an ambiguity.  In that case, the task will request
             that you use FREQID.
  BIF........First IF to copy. 0=>all.
  EIF........Highest IF to copy. 0=>all higher than BIF
  BCHAN......First channel to copy. 0=>all.
  ECHAN......Highest channel to copy. 0=>all higher than BIF
  SUBARRAY...Subarray number to copy. 0=>all.
  DOCALIB....If true (>0), calibrate the data using information in the
             specified Cal (CL) table for multi-source or SN table for
             single-source data.  Also calibrate the weights unless
             DOCALIB > 99 (use this for old non-physical weights).
  GAINUSE....Version number of the CL table to apply to
             multisource files or the SN table for single
             source files.  0 => highest.
  DOPOL......If > 0 then correct data for instrumental polarization as
             represented in the AN or PD table.  This correction is
             only useful if PCAL has been run or feed polarization
             parameters have been otherwise obtained.  See HELP DOPOL
             for available correction modes: 1 is normal, 2 and 3 are
             for VLBI.  1-3 use a PD table if available; 6, 7, 8 are
             the same but use the AN (continuum solution) even if a PD
             table is present.
  PDVER......PD table to apply if PCAL was run with SPECTRAL true and
             0 < DOPOL < 6.  <= 0 => highest.
  BLVER......Version number of the baseline based calibration
             (BL) table to appply. <0 => apply no BL table,
             0 => highest.
  FLAGVER....specifies the version of the flagging table to be
             applied. 0 => highest numbered table.
             <0 => no flagging to be applied.
  DOBAND.....If true (>0) then correct the data for the shape of the
             antenna bandpasses using the BP table specified by BPVER.
             The correction has five modes:
             (a) if DOBAND=1 all entries for an antenna in the table
             are averaged together before correcting the data.
             (b) if DOBAND=2 the entry nearest in time (including
             solution weights) is used to correct the data.
             (c) if DOBAND=3 the table entries are interpolated in
             time (using solution weights) and the data are then
             corrected.
             (d) if DOBAND=4 the entry nearest in time (ignoring
             solution weights) is used to correct the data.
             (e) if DOBAND=5 the table entries are interpolated in
             time (ignoring solution weights) and the data are then
             corrected.
  BPVER......Specifies the version of the BP table to be applied
             plotted (if APARM(8)=2) or applied (if DOBAND > 0
             and APARM(8) .NE. 2). 0 => highest numbered table.
             <0 => no bandpass correction to be applied.
  SMOOTH.....Specifies the type of spectral smoothing to be applied to
             a uv database . The default is not to apply any smoothing.
             The elements of SMOOTH are as follows:
             SMOOTH(1) = type of smoothing to apply: 0 => no smoothing
               To smooth before applying bandpass calibration
                 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc
               To smooth after applying bandpass calibration
                 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc
             SMOOTH(2) = the "diameter" of the function, i.e. width
               between first nulls of Hanning triangle and sinc
               function, FWHM of Gaussian, width of Boxcar. Defaults
               (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) =
               1 - 4 and 5 - 8, resp.
             SMOOTH(3) = the diameter over which the convolving
               function has value - in channels.  Defaults: 1,3,1,4
               times SMOOTH(2) used when input SMOOTH(3) < net
               SMOOTH(2).
  OUTVER.....Output AS table version number. 0=>new table.
               If the table already exists then new data will be
               appended to the end of the table.
  BADDISK....The disk numbers to avoid for scratch files (sorting
             tables mostly).

EXPLAIN SECTION