AIPS NRAO AIPS HELP file for SPRMS in 31DEC24



As of Fri Apr 26 19:45:49 2024


SPRMS: Plots spectral statistics of a subset of a uv data set

INPUTS

INNAME                             Input UV file name (name)
INCLASS                            Input UV file name (class)
INSEQ             0.0     9999.0   Input UV file name (seq. #)
INDISK            0.0        9.0   Input UV file disk unit #
SOURCES                            Source name
QUAL            -10.0              Calibrator qualifier -1=>all
CALCODE                            Calibrator code '    '=>all
STOKES                             Stokes of output
TIMERANG                           Time range to use
SELBAND                            Bandwidth to select (kHz)
SELFREQ                            Frequency to select (MHz)
FREQID                             Freq. ID to select.
ANTENNAS                           Antennas to include 0=>all
BASELINE                           Baselines with ANTENNAS
UVRANGE                            UV range in kilolambda.
SUBARRAY          0.0     1000.0   Sub-array, 0=>all
BIF                                Low IF number included
EIF                                Highest IF number included
BCHAN             0.0              First channel included
ECHAN             0.0              last channel included
DOCALIB          -1.0      101.0   > 0 calibrate data & weights
                                   > 99 do NOT calibrate weights
GAINUSE                            CL (or SN) table to apply
DOPOL            -1.0       10.0   If >0.5 correct polarization.
PDVER                              PD table to apply (DOPOL>0)
BLVER                              BL table to apply.
FLAGVER                            Flag table version
DOBAND           -1.0       10.0   If >0.5 apply bandpass cal.
                                   Method used depends on value
                                   of DOBAND (see HELP file).
BPVER                              Bandpass table version
SMOOTH                             Smoothing function. See
                                   HELP SMOOTH for details.
OPTYPE                             Desired parameter: AMP,
                                   PHAS, REAL, IMAG, AUTO,
                                   SAMP
DOWEIGHT                           > 0 use weights when
                                   averaging over baselines
SOLINT                             Averaging time (min)
PIXRANGE                           Range of values in plot
                                   of mean
APARM                              (1,2) range of values in
                                   plot of standard deviation
FACTOR                             Scale points by abs(FACTOR)
                                   < 0 -> also connect lines
DOTV                               > 0 -> plot on TV, else make
                                   a plot file
GRCHAN                             Graphics channel to use
LTYPE        -410.0       410.0    Type of labeling: 1 border,
                                   2 no ticks, 3 - 6 standard,
                                   7 - 10 only tick labels
                                   <0 -> no date/time
BADDISK                            Disks to avoid for scratch

HELP SECTION

SPRMS
Task:  This task applies calibration to a selected subset of a uv
       data file and then averages all included data as a function
       of spectral channel over the stated averaging time.  The
       results are then averaged to determine mean and standard
       deviation.  Two plots are then generated.
Adverbs:
  INNAME.....Input UV file name (name).      Standard defaults.
  INCLASS....Input UV file name (class).     Standard defaults.
  INSEQ......Input UV file name (seq. #).    0 => highest.
  INDISK.....Disk drive # of input UV file.  0 => any.
  SOURCES....Source to be included.   '  '=> all; if any starts with a
             '-' then all except ANY source named.
  QUAL.......Qualifier of source to be included. -1 => all.
  CALCODE....Calibrator code of sources to include. ' '=> all.
  STOKES.....Specifies which STOKES parameter is included.
               'I','Q','U','V', 'RR','LL', 'RL', 'LR',
               'VV','HH', 'VH', 'HV'
             Note: only 1 Stokes allowed.
  TIMERANG...Time range of the data to be included. In order: Start day,
             hour, min. sec, end day, hour, min. sec. Days relative to
             ref. date.
  SELBAND....Bandwidth of data to be selected. If more than one IF is
             present SELBAND is the width of the first IF required.
             Units = kHz. For data which contain multiple
             bandwidths/frequencies the task will insist that some form
             of selection be made by frequency or bandwidth.
  SELFREQ....Frequency of data to be selected. If more than one IF is
             present SELFREQ is the frequency of the first IF required.
             Units = MHz.
  FREQID.....Frequency identifier to select (you may determine which is
             applicable from the OPTYPE='SCAN' listing produced by
             LISTR). If either SELBAND or SELFREQ are set, their values
             override that of FREQID.  However, setting SELBAND and
             SELFREQ may result in an ambiguity.  In that case, the task
             will request that you use FREQID.
  ANTENNAS...A list of the antennas to be included.  All 0 => all.
             If any number is negative then all antennas listed are NOT
             included and all others are.
  BASELINE...Baselines between antennas named in ANTENNAS and those
             named in BASELINE are selected..  There are four possible
             combinations of ANTENNAS and BASELINE:
             1. ANTENNAS = 0; BASELINE = 0.
                All possible baselines are selected.
             2. ANTENNAS <>0; BASELINE = 0.
                a)All ANTENNAS > 0
                  Baselines including an antenna in the ANTENNAS list
                  are selected;
                b)Some ANTENNAS < 0
                  All baselines NOT including an antenna in the ANTENNAS
                  list are selected;
             3. ANTENNAS = 0; BASELINE <> 0.
                a)All BASELINE > 0
                  Baselines including an antenna in the BASELINE list
                  are selected;
                b)Some BASELINE < 0
                  All baselines NOT including an antenna in the BASELINE
                  list are selected;
             4. ANTENNAS <> 0; BASELINE <> 0.
                a)All ANTENNAS>0 and all BASELINE>0
                  Baselines between antennas named in ANTENNAS and those
                  named in BASELINE are selected.
                b)Some ANTENNAS<0 .OR. some BASELINE<0
                  Baselines between antennas named in ANTENNAS  and
                  those named in BASELINE are DE-selected, all others
                  are selected.
  UVRANGE....Range of projected spacings to be plotted in 1000's of
             wavelengths.  0  =>  1, 1.E10
  SUBARRAY...Sub-array number to include. 0=>all.
  BIF........First IF to include.  0 -> 1.
  EIF........Last IF to include.   0 -> max.
  BCHAN......First channel to include. 0=>all.
  ECHAN......Highest channel to include. 0=>all higher than BCHAN
  DOCALIB....If true (>0), calibrate the data using information in the
             specified Cal (CL) table for multi-source or SN table for
             single-source data.  Also calibrate the weights unless
             DOCALIB > 99 (use this for old non-physical weights).
  GAINUSE....version number of the CL table to apply to multi-source
             files or the SN table for single source files.
             0 => highest.
  DOPOL......If > 0 then correct data for instrumental polarization as
             represented in the AN or PD table.  This correction is
             only useful if PCAL has been run or feed polarization
             parameters have been otherwise obtained.  See HELP DOPOL
             for available correction modes: 1 is normal, 2 and 3 are
             for VLBI.  1-3 use a PD table if available; 6, 7, 8 are
             the same but use the AN (continuum solution) even if a PD
             table is present.
  PDVER......PD table to apply if PCAL was run with SPECTRAL true and
             0 < DOPOL < 6.  <= 0 => highest.
  BLVER......Version number of the baseline based calibration (BL) table
             to apply. <0 => apply no BL table, 0 => highest.
  FLAGVER....specifies the version of the flagging table to be applied.
              0 => highest numbered table.
             <0 => no flagging to be applied.
  DOBAND.....If true (>0) then correct the data for the shape of the
             antenna bandpasses using the BP table specified by BPVER.
             The correction has five modes:
             (a) if DOBAND=1 all entries for an antenna in the table
             are averaged together before correcting the data.
             (b) if DOBAND=2 the entry nearest in time (including
             solution weights) is used to correct the data.
             (c) if DOBAND=3 the table entries are interpolated in
             time (using solution weights) and the data are then
             corrected.
             (d) if DOBAND=4 the entry nearest in time (ignoring
             solution weights) is used to correct the data.
             (e) if DOBAND=5 the table entries are interpolated in
             time (ignoring solution weights) and the data are then
             corrected.
             IMAGR uses DOBAND as the nearest integer; 0.1 is therefore
             "false".
  BPVER......Specifies the version of the BP table to be applied
                0 => highest numbered table.
               <0 => no bandpass correction to be applied.
  SMOOTH.....Specifies the type of spectral smoothing to be applied to
             a uv database . The default is not to apply any smoothing.
             The elements of SMOOTH are as follows:
             SMOOTH(1) = type of smoothing to apply: 0 => no smoothing
               To smooth before applying bandpass calibration
                 1 => Hanning, 2 => Gaussian, 3 => Boxcar, 4 => Sinc
               To smooth after applying bandpass calibration
                 5 => Hanning, 6 => Gaussian, 7 => Boxcar, 8 => Sinc
             SMOOTH(2) = the "diameter" of the function, i.e. width
               between first nulls of Hanning triangle and sinc
               function, FWHM of Gaussian, width of Boxcar. Defaults
               (if < 0.1) are 4, 2, 2 and 3 channels for SMOOTH(1) =
               1 - 4 and 5 - 8, resp.
             SMOOTH(3) = the diameter over which the convolving
               function has value - in channels.  Defaults: 1,3,1,4
               times SMOOTH(2) used when input SMOOTH(3) < net
               SMOOTH(2).
  OPTYPE.....Type of data examined: 'AMP', 'PHAS', 'REAL', 'IMAG',
             'SAMP' (scalar amplitude between baselines, times)
             'AUTO' (autocorrelations only)  else 'AMP'
             'SAMP' selects scalar averaging between SOLINT intervals
             (with vector averaging being used within SOLINT when
             DOWEIGHT <= 0) or scalar averaging over all samples when
             DOWEIGHT > 0.  'AMP selects vector averaging over all
             baselines and times in the included data set.
  DOWEIGHT...If DOWEIGHT > 0, data weights are used when averaging
             multiple baselines and times.  Note that in this case,
             SOLINT is ignored.  If DOWEIGHT <= 0, the task uses data
             weights to average over the time interval, but weights
             each time interval equally.
  SOLINT.....Averaging time in minutes: 0 -> 0.007
  PIXRANGE...Range of values in plot of mean.  0 -> min to max
  APARM......If APARM(2) > APARM(1), use this range when pltting the
             standard deviation.
  FACTOR.....Scale the pointed plots by abs(FACTOR).  0 -> 1.0
             If < 0, also connect the plotted points with lines.
  DOTV.......> 0 => plot directly on the TV device, otherwise make a
             plot file for later display on one or more devices
             (including the TV if desired).
  GRCHAN.....Graphics channel to use.  0 -> multiple
  LTYPE......Labelling type, see HELP LTYPE for details:
             1 = border, 2 = no ticks, 3 or 7 = standard, 4 or 8 =
             relative to ref. pixel, 5 or 9 = relative to subimage
             (BLC, TRC) center, 6 or 10 = pixels.  7-10 all labels
             other than tick numbers and axis type are omitted.
             Less than 0 is the same except that the plot file
             version number and create time are omitted.
             Add n * 100 to alter the metric scaling.
  BADDISK....The disk numbers to avoid for scratch files (sorting
             tables mostly).

EXPLAIN SECTION


AIPS